Model | HZ - 80 (A~G) | HZ - 150 (A~G) | HZ - 225 (A~G) | HZ - 408 (A~G) | HZ - 608 (A~G) | HZ - 800 (A~G) | HZ - 1000 (A~G) |
---|---|---|---|---|---|---|---|
Internal Dimensions (Width × Height × Depth, cm) | 40×50×40 | 50×60×50 | 60×75×50 | 80×85×60 | 80×95×80 | 100×100×80 | 100×100×100 |
External Dimensions (Width × Height × Depth, cm) | 90×136×94 | 100×146×104 | 100×161×117 | 110×171×137 | 130×181×137 | 150×186×137 | 150×186×157 |
Temperature Range | -70°C~+100°C (150°C) (A: +25°C B: 0°C C: -20°C D: -40°C E: -50°C F: -60°C G: -70°C) | ||||||
Humidity Range | Within +20°C~+85°C, 20%~98%R.H. (10%-98%R.H/5%~98%R.H for special conditions) | ||||||
Temperature and Humidity Resolution Accuracy | ±0.1°C; ±0.1%R.H. (Minimum unit distinguishable by instrument) | ||||||
Temperature and Humidity Uniformity | For ≤150L: ±1.0°C; ±2.0%R.H. For >150L - <1m³: ±2.0°C; ±3.0%R.H. | ||||||
Temperature and Humidity Fluctuation | For ≤150L: ≤1°C; ±2.0%R.H. For >150L - <1m³: ≤2°C; ±3.0%R.H. | ||||||
Temperature and Humidity Control Accuracy | ±1.0°C; ±2.0%R.H. (Error between displayed and actual values) | ||||||
Heating Time | Approx. 2 - 3.0°C/min | ||||||
Cooling Time | Approx. 1.0°C/min (5 - 10°C/min for special conditions) | ||||||
Cooling System | Air - cooled/Single - stage Compressor (-20°C), Air & Water - cooled/Dual - stage Compressor (-40°C~-70°C) |
Model | HZ - 80 (A~G) | HZ - 150 (A~G) | HZ - 225 (A~G) | HZ - 408 (A~G) | HZ - 608 (A~G) | HZ - 800 (A~G) | HZ - 1000 (A~G) |
---|---|---|---|---|---|---|---|
Internal Dimensions (Width × Height × Depth, cm) | 40×50×40 | 50×60×50 | 60×75×50 | 80×85×60 | 80×95×80 | 100×100×80 | 100×100×100 |
External Dimensions (Width × Height × Depth, cm) | 90×136×94 | 100×146×104 | 100×161×117 | 110×171×137 | 130×181×137 | 150×186×137 | 150×186×157 |
Temperature Range | -70°C~+100°C (150°C) (A: +25°C B: 0°C C: -20°C D: -40°C E: -50°C F: -60°C G: -70°C) | ||||||
Humidity Range | Within +20°C~+85°C, 20%~98%R.H. (10%-98%R.H/5%~98%R.H for special conditions) | ||||||
Temperature and Humidity Resolution Accuracy | ±0.1°C; ±0.1%R.H. (Minimum unit distinguishable by instrument) | ||||||
Temperature and Humidity Uniformity | For ≤150L: ±1.0°C; ±2.0%R.H. For >150L - <1m³: ±2.0°C; ±3.0%R.H. | ||||||
Temperature and Humidity Fluctuation | For ≤150L: ≤1°C; ±2.0%R.H. For >150L - <1m³: ≤2°C; ±3.0%R.H. | ||||||
Temperature and Humidity Control Accuracy | ±1.0°C; ±2.0%R.H. (Error between displayed and actual values) | ||||||
Heating Time | Approx. 2 - 3.0°C/min | ||||||
Cooling Time | Approx. 1.0°C/min (5 - 10°C/min for special conditions) | ||||||
Cooling System | Air - cooled/Single - stage Compressor (-20°C), Air & Water - cooled/Dual - stage Compressor (-40°C~-70°C) |